上海金畔生物科技有限公司代理日本同仁化学试剂盒全线产品,欢迎访问日本同仁化学dojindo官网了解更多信息。
DOPP
DOPP
- イオン電極用試薬
イオン電極用試薬―液膜型イオン電極用溶媒
-
製品コードD016 DOPP
-
CAS番号1754-47-8
-
化学名Di-n-octyl phenylphosphonate
-
分子式・分子量C22H39O3P=382.52
容 量 | メーカー希望 小売価格 |
富士フイルム 和光純薬 |
---|---|---|
1 g | ¥24,000 | 347-04701 |
5 g | ¥84,300 | 343-04703 |
- ご購入方法
- お問い合わせ
マニュアル
-
プロトコル イオン濃度を電極で測りたい
参考文献
1) G. H. Griffiths, G. J. Moody and J. D. R. Thomas, "An Investigation of the Optimum Composition of Poly(Vinyl Chloride)Matrix Membranes Used for Selective Calcium-Sensitive Electrodes", Analyst, 1972, 97, 420.
2) A. J. Frend, G. J. Moody and J. D. R. Thomas, "Studies of Calcium Ion-selective Electrodes in the Presence of Anionic Surfactants", Analyst, 1983, 108, 1072.
3) S. A. H. Khalil, G. J. Moody and J. D. R. Thomas, "Studies of Calcium Ion-selective Electrodes in the Presence of Biochemical Materials", Analyst, 1985, 110, 353.
4) V. P. Y. Gadzekpo, G. J. Moody and D. R. Thomas, "Coated-Wire Lithium Ion-Selective Electrodes Based on Polyalkoxylate Complexes", Analyst, 1985, 110, 1381.
5) K. Hiratani, T. Okada and H. Sugihara, "Di-n-Octyl Phenyl Phosphonate: a Plasticizer of Poly(Vinyl Chloride)Matrix Membrane Electrodes Behaving as a Li+– Selective Agent", Bull. Chem. Soc. Jpn., 1986, 59, 2015.
6) Sajedah A. H. Khalil, G. J. Moody, J. D. R. Thomas and Jose L. F. C. Lima, "Epoxy-Based All-Solid-State Poly(Vinyl Chloride) Matrix Membrane Calcium Ion-Selective Microelectrodes", Analyst, 1986, 111, 611.
7) T. Okada, H. Sugihara and K. Hiratani, "Calcium-Selective Electrodes Based on Noncyclicpolyether Diamides", Anal. Chim. Acta, 1986, 186, 307.
8) H. Sakamoto, K. Kimura and T. Shono, "Lithium Separation and Enrichment by Proton-Driven Cation Transport through Liquid Membranes of Lipophilic Crown Nitrophenols", Anal. Chem., 1987, 59, 1513.
9) K. Hiratani, T. Okada and H. Sugihara, "1, 3-Bis(8-quinolyloxy)propane Derivatives as Neutral Carriers for Lithium Ion Selective Electrodes", Anal. Chem., 1987, 59, 767.
10) K. Kimura, H. Oishi, T. Miura and T. Shono, "Lithuim Ion Selective Electrodes Based on Crown Ethers for Serum Lithium Assay", Anal. Chem. , 1987, 59, 2331.
11) T. Okada, K. Hiratani and H. Sugihara, "Use of Lipophilic Additives for the Improvement of the Characteristics of PVC Membrane Lithium-selective Electrodesbased on Non-Cyclic Neutral Carriers", Analyst, 1987, 112, 587.
12) A. M. Y. Jaber, G. J. Moody and J. D. R. Thomas, "Studies on Lead Ion-selective Electrodes Based on Polyalkoxylates", Analyst, 1988, 113, 1409.
13) F. N. Assubaie, G. J. Moody and D. R. Thomast, "Guanidinium Ion-Selective Electrodes Based on Dibenzo-27-Crown-9 and Tetraphenylborate", Analyst, 1988, 113, 61.
14) H. Wang, "Properties of DOPP in Plasticized PVC Membranes", J. Electroanal. Chem., 1995, 382, 165.
取扱条件
性状: | 本品は、無色液体である。 |
---|---|
純度(GC): | 95.0% 以上 |
屈折率(25℃): | 1.473~1.477 |
薄層クロマトグラフィー: | 試験適合 |
IRスペクトル: | 試験適合 |